don’t take the chance!
The Electrical Safety office is alerting all Plumbers , Gasfitters and fitters. To Always use a bonding strap to bridge the gap when cutting into any pipework, when disconnecting gas appliances or water appliances , removing gas meters, gas valves and breaking into a pipework system.
It is also recommended to add Earth strap to a known Earth bond, to further neutralise the effects of stray current. If you want to check for stray current- use a milli AMP clamp Amp meter around the pipework in addition to the bonding straps and earth bond. Stray currents in excess of 20mA has the potential to be fatal. Recently there has been several deaths caused by plumbers cutting into a water pipe with no bonding straps. Remember any stray current will find the path of least resistance to Earth , which could be your body !
Did you know ! Our disconnect and reconnect gas appliances unit, covers safe work methods of how to safely use bridging straps , why not complete just one unit in the module, just ask us for more information contact us about our bite size units on how to gas and electrical refresher courses. contact Bizmatrix Education 0457 595 888 or 1300 588 749 or go to Gas refresher/ trade tests and field experience or Certificate IV gas units course or electrical skills maintenance